What a backflow test is

Last updated

What a backflow test checks, how cross-connections threaten drinking water, and why the field test belongs to a qualified tester.

A backflow test is a field check of a mechanical assembly that is supposed to stop used or non-drinking water from flowing backward into a drinking-water pipe. It is not a home experiment, and it is not the same thing as a water-quality sample from the kitchen tap. The U.S. Environmental Protection Agency’s Cross-Connection Control Manual describes plumbing cross-connections as actual or potential connections between a potable and a nonpotable water supply, and it calls them a serious public health hazard. The manual was written for health officials, waterworks personnel, and plumbers. It is educational guidance. It is not a national license to test.

Two ways water can reverse

EPA’s manual explains that backflow needs two things: a link between the drinking-water pipe and something else, and a force that pushes or pulls toward the drinking-water side. One force is backsiphonage. Pressure in the drinking-water pipe drops, for example during a main break or heavy firefighting use, and water is siphoned from a hose, a tank, or a piece of equipment. The other force is backpressure. Something on the customer’s side, such as a pump or a boiler, is at higher pressure than the city main and pushes fluid toward the public system. Arizona’s Department of Environmental Quality uses the same split: back pressure, back siphonage, or both.

A shut valve is not that protection. The assemblies that get a field test are built so a trained person can tell whether the checks still hold. The test asks whether the installed assembly still works, usually when it is new, after it is repaired or moved, and on a repeating schedule. Arizona says required assemblies are tested at least annually and also after installation, relocation, or repair. Texas says a person who tests the installation or operation of an assembly must hold a state license. Those are duties, not steps to copy onto a gauge.

An air gap is different. It is open space between the end of a pipe and the flood rim of a tank or drain. EPA’s manual says an air gap is generally twice the supply-pipe diameter and never less than one inch. Arizona uses that same minimum. An air gap is often checked by looking, not by hooking up a differential gauge. A reduced-pressure principle assembly, a double check, or a pressure vacuum breaker is the mechanical equipment that gets the gauge test. Which one belongs on a given pipe depends on the hazard. This guide does not tell you how to choose or install one.

Why utilities send the letter

EPA’s primacy page explains that states, and some tribes, take on primary enforcement of the Safe Drinking Water Act when they qualify. The state drinking-water agency writes the cross-connection expectations, and the water supplier carries them out. EPA’s Total Coliform Rule help page points systems to cross-connection guidance because an unprotected connection can let contamination into the distribution system. The letter in your mailbox is the supplier enforcing that program.

There is no federal backflow-tester license on the EPA pages that describe primacy or the cross-connection manual. The manual trains and informs. The license, registration, or accepted third-party card is a state or local decision. Texas issues a Backflow Prevention Assembly Tester license. Other states certify testers themselves, accept a named organization, or leave the acceptable credential to the water supplier. Who is allowed to test walks through that split.

What you should get back

A real test ends with a report. The report identifies the assembly, the date, the result, and the person who tested. Many states also expect a tag on the assembly. The report goes to you and, when the rule says so, to the water supplier. Keep it. If the assembly fails, the next step is repair or replacement by someone allowed to do that work, then another test. What a failed test means covers that outcome without describing how to take the assembly apart.

If a seller or a contractor offers to “show you how to test it yourself,” decline. The gauge procedure is in training courses and in manuals aimed at certified testers. Doing it yourself can produce a number a water supplier will not accept, and it can leave a protection device offline. Hire the person whose credential the supplier recognizes, and read Questions to ask before you hire a tester before you book the visit.

Sources

  1. Cross-Connection Control Manual, February 2003
  2. Total Coliform Rule Compliance Help for Public Water Systems
  3. Primacy Enforcement Responsibility for Public Water Systems
  4. Arizona Department of Environmental Quality, Backflow Prevention
  5. Texas Commission on Environmental Quality, Backflow Prevention Assembly Tester